Mimesis 22S - Analog Preamplifier
- Ultra-high Performance Analogue Line Preamplifier using new Goldmund ultra-low noise analogue technology.
- Full Dual-Mono construction with processor driven attenuators linked.
- Uses 2 x Goldmund 22S modules (one per channel) with temperature control.
- Separate built-in power supply unit for optimum noise reduction.
- 3-step regulation in the power supply with 8 separate circuits.
- 7 x inputs and 2 x analogue tape loops. 3 inputs with balanced or unbalanced.
Balanced and Unbalanced analogue output circuits.
- OUTPUT LEVEL
- Nominal level: 1.55 V RMS
- Maximum output level (balanced) : 9.6 V RMS
- Maximum output level (unbalanced): 4.8 V RMS
- Output impedance: 50 Ohms
- FREQUENCY RESPONSE
- These values for any level to 10 V RMS:
- +/- 0 dB, 20 - 20 kHz
- +/- 3 dB, 0.2 – 1.2 MHz
- INPUT SENSITIVITY
- Nominal level: 100 mV
- Saturation level: 5 V RMS
- Nominal input impedance: 39 kOhms
- Separated input level adjustment for each of the 7 line inputs: -12 to 12 dB
- INPUT LEVEL
- Maximum input level (balanced) : 9.6 V RMS
- Maximum input level (unbalanced): 4.8 V RMS
- GROUP DELAY
- Propagation delay <300 ns stable with frequency from DC to 200 kHz
- DISTORTION
- 1 V rms output level, 80 KHz measurement bandwidth, 600 ohms termination
impedance
- THD unbalanced in to unbalanced out 0.0002% flat with frequency
- THD balanced in to balanced out 0.0001%
flat with frequency
- IMD unbalanced in to unbalanced out 0.0002%
- IMD balanced in to balanced out 0.0001%
- Slew rate of the amplification stages: 2500V/us
- Rise time: < 400 ns
- CROSSTALK
- Separation: > 105 dB between channels (20Hz – 20kHz)
- NOISE
- Signal-to noise ratio on line input: > 120 dB (0.01 Hz - 10 Mhz)
- Weighted ASA A: > 130 dB
- OPERATING TEMPERATURE
- Room temperature: -30 to +40 degrees Celsius ( -22 to +104 degrees Fahrenheit)
- Internal temperature: +45 to +70 degrees Celsius ( +113 to +158 degrees Fahrenheit)
- POWER SUPPLY
- Nominal line voltage: 117 or 234 V
- Input voltage range: +/- 10 %
- Maximum power consumption: 70 W
- GROUNDING
- Separated ground and earth signal
- Connection optional between earth and ground to cancel all ground loops
- SAFETY FEATURES
- Automatic switching to MUTING if the AC line drops or is interrupted
- Automatic protection against tape loops
- FRONT PANEL CONTROLS
- Muting/Power switch with Led control
- Volume control
- Balance control
- Record/Menu switch
- Phase/Edit switch
- 7 Input Control switches (with Led control)
- Power connector
- Earthing post (yellow-green)
- Output connectors RCA (right and left)
- Output connectors RCA (right and left) for Tape 1 and Tape 2
- Signal grounding post (black)
- Input connectors RCA (right and left) for Tape and line inputs
- Link float
- RS232 Connector
- POWER SUPPLY CONTROLS
- Power cord socket (3 lugs)
- Mains Fuse (2.5A slow-blow)
- Voltage Selector 110/220 V
- SIZE AND WEIGHT
- Preamplifier: 440 W x 375 D x 140 H (mm)
- Power Supply: 440 W x 300 D x 80 H (mm)
- Total Weight: 25 kg
- WARRANTY
Download User Manual